Miyashita, Kotaro
ORCID: 0009-0006-8956-214X, Shih, Chun-Ting
ORCID: 0009-0002-6779-5605, Bianchini, Emiliano, Oshima, Asahi
ORCID: 0009-0003-9635-6975, Kanehama, Nozomu, Tsai, Tsung-Ying
ORCID: 0000-0002-0426-9360, Miyashita, Maya, Colombo, Antonio
ORCID: 0000-0002-2940-2455, Reimers, Bernhard et al
(2026)
Impact of Suspected Intraluminal Thrombus on Angiographic Outcomes in Patients Treated With Drug-Coated Balloon Angioplasty.
Journal of the Society for Cardiovascular Angiography & Interventions
.
p. 105674.
(In Press)
Preview |
PDF (VOR (In Press, Corrected Proof))
- Published Version
Available under License Creative Commons Attribution. 9MB |
Official URL: https://doi.org/10.1016/j.jscai.2026.105674
Abstract
Background
The impact of suspected intraluminal thrombus (SIT) on angiographic outcomes in patients with small-vessel coronary artery disease treated with drug-coated balloons (DCB) remains unclear.
Methods
In the TReAtmeNt of Small Coronary Vessels: MagicTouch Sirolimus Coated Balloon (TRANSFORM I) substudy, optical coherence tomography was performed after predilation and before DCB use in 104 lesions (97 patients) to confirm the presence or absence of SIT. SIT was located in the dissected area, attached to the luminal surface (LS), or to the tip of the dissection flap. Artificial intelligence–driven analyses quantified the SIT volume and its optical characteristics (intensity, attenuation, and backscattering) to help differentiate red from white SIT. Quantitative coronary angiography and angiography-derived fractional flow reserve were assessed at the 6-month follow-up.
Results
Suspected intraluminal thrombus was identified in 46 of 104 lesions (44.2%). At 6 months, SIT lesions compared with non-SIT lesions had smaller minimum lumen diameters (1.21 vs 1.32 mm, P = .03), larger percent diameter stenoses (42% vs 36%, P = .03), and higher rates of binary restenosis (37.0% vs 13.8%, P = .01). Subgroup analyses did not demonstrate any significant interaction between the DCB type and the impact of SIT on worse angiographic outcomes (Pinteraction = .391). In multivariable logistic regression, LS SIT (odds ratio, 3.66; 95% CI, 1.11-12.83; P = .036) and the DCB type (MagicTouch vs SeQuent, odds ratio, 4.11; 95% CI, 1.14-13.88; P = .015) emerged as independent predictors of binary restenosis.
Conclusions
Despite comparable postprocedural anatomic and physiological results, the observation of LS SIT on optical coherence tomography after predilatation and before DCB angioplasty was associated with adverse angiographic outcomes at 6 months.
Repository Staff Only: item control page
Tools
Tools